SW1 Dip Switch Configurations
Tables 3-9 through 3-12 detail the switch settings
for the possible system configurations.
OPEN = Off (No)
CLOSED = On (Yes)
1500126A
OPEN
DISPL OR LED
REM CFG Y/N
FRT PNL LOCK Y/N
RF DET Y/N
FAULT UNIT/ALL
REM ANALG Y/N
Figure 3-9 SW1 Dip Switch Configurations
Table 3-9 Single System Operating Locally
Power
Supply
SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 Suggested Settings
Standalone
(Set Front
Panel to:
Local)
Rem Analog
Open/OFF
Fault
Open/OFF
RF Detector
Closed/ON
Rem Only
Open/OFF
Rem CFG
Open/OFF =
Disabled
Closed/ON =
Enabled
Display or
LED
Closed/ON =
Num
OPEN
Table 3-10 Single System Operating Remotely
Power
Supply
SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 Sugessted Settings
Standalone
(Set Front
Panel to:
Remote)
Rem Analog
Open/OFF
Fault
Open/OFF
RF Detector
Closed/ON
Rem Only
Open/OFF =
Disabled
Closed/ON =
Enabled
Rem CFG
Open/OFF =
Disabled
Closed/ON =
Enabled
Display or
LED
Closed/ON =
Num
OPEN
Table 3-11 Networked System Operating Locally
Power
Supply
SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 Sugessted Settings
Master
(Set Front
Panel to:
Local)
Rem Analog
Open/OFF
Fault
Open/OFF
RF Detector
Closed/ON
Rem Only
Open/OFF =
Disabled
Closed/ON =
Enabled
Rem CFG
Open/OFF =
Disabled
Closed/ON =
Enabled
Display or
LED
Closed/ON =
Num
OPEN
Remote
(Set Front
Panel to:
Local)
Rem Analog
Open/OFF
Fault
Single =
Closed/ON
All =
Open/OFF
RF Detector
Yes =
Closed/ON
No =
Open/OFF
Rem Only
Open/OFF =
Disabled
Closed/ON =
Enabled
Rem CFG
Open/OFF =
Disabled
Closed/ON =
Enabled
Display or
LED
Closed/ON =
Num
OPEN
Table 3-12 Networked System Operating Remotely
Power
Supply
SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 Sugested Settings
Master
(Set Front
Panel to:
Remote)
Rem Analog
Open/OFF
Fault
Single =
Closed/ON
All =
Open/OFF
RF Detector
Closed/ON
Rem Only
Open/OFF =
Disabled
Closed/ON =
Enabled
Rem CFG
Open/OFF =
Disabled
Closed/ON =
Enabled
Display or
LED
Closed/ON =
Num
OPEN
Remote
(Set Front
Panel to:
Remote
Rem Analog
Open/OFF
Fault
Single =
Closed/ON
All =
Open/OFF
RF Detector
Yes =
Closed/ON
No =
Open/OFF
Rem Only
Open/OFF =
Disabled
Closed/ON =
Enabled
Rem CFG
Open/OFF =
Disabled
Closed/ON =
Enabled
Display or
LED
Closed/ON =
Num
OPEN