Novatel 15aT Car Satellite TV System User Manual


 
60 EuroPak-15a Receiver User Manual Rev 5
Chapter 5 Commands
Examples:
LOG COM1 PSRPOSA ONTIME 7 2.5 HOLD
LOG COM3 PRSPOSA ONCE
The first example configures the EuroPak-15a to output the PSRPOS log in ASCII format to COM1 at 7 second
intervals offset by 2.5 seconds (output at 2.5 seconds then 9.5 seconds and so on). The second example outputs
the log only once on COM3.
Table 27: Log Trigger Values
Table 28: Log Hold Values
ASCII Binary Description
ONNEW 0
Output when the message is updated (not
necessarily changed).
ONCHANGED 1 Output when the message is changed.
ONTIME 2 Output on a time interval.
ONNEXT 3 Output only the next message.
ONCE 4 Output only the current message.
ASCII Binary Description
NOHOLD 0
Allow log to be removed by the
UNLOGALL command.
HOLD 1
Prevent log from being removed by the
UNLOGALL command.