RTM-ATCA-SXXX Overview
6806800H62B ATCAS201InstallationandUseGuide120
Figure 37, Ethernet Management Port
11.3.3 Serial Console Port (RJ-45)
An RS232 serial console port is provided on the RTM-ATCA-SXXX to facilitate a pass-
through communication path to certain ATCA board products. The port uses an
RJ45 connector.
11.4 LEDs
The following LEDs are located on the face plate of the RTM-ATCA-SXXX.
Table 56 LEDs On RTM Faceplate
LED RTM Faceplate
On LAN management activity LED Ethernet Activity AMBER
Off No Activity
On LAN management LINK LED Ethernet Link GREEN
Off No Link
On Management power available to the module
and the module can safely be extracted
Off The module is operational and is unsafe for
extraction
Long Blink Delay before module is activated
Hot Swap (HS) BLUE
Short Blink Delay before module is de-activated
On Module Fault set by Shelf manager or
12V payload power not detected.
Fault or “Out of Service” (OOS) RED
Off No module fault
12V payload power is being supplied to board
On 12V payload power is being supplied to board Module Ready (OK) and “in service” GREEN
Off 12V payload power is not detected