A SERVICE OF

logo

ATCAS201Installation
6806800H62B ATCAS201InstallationandUseGuide19
2.10.1 To Verify the Hardware Installation
1. After power is applied to the system, wait approximately 45 seconds for
firmware to initialize the board.
2. Inspect the LEDs on the front of the ATCA panel. When properly installed and
powered, the LEDs will illuminate as follows:
ATCA Hot Swap LED Off: Normal, default state
ATCA Health status Green-blinking: Healthy, OK
ATCA Out of service (OOS) Off: Normal, default state
3. (Optional). There are five Ethernet ports on the ATCA blade:
1 management (on RTM)
2 ATCA base ports (zone-2 connector)
2 ATCA fabric ports (zone-2 connector)
If DHCP is running on the network, it is possible to immediately ping the
Ethernet ports on the ATCA module. Open a command line window on any
node, and attempt to ping the ATCA blade.
ok ping 192.168.1.xxx
Note1: Ping requires that you determine the IP address assigned to the blade. The
carrier blades MAC address assignments are registered with the IANA public section
of the IEEE Standards OUI (Organizational unique identifier) database. The Ethernet
ports for the blade can be identified by finding the IP address corresponding to the
following MAC address assignments:
MAC address OUI
00-11-0D-xx-xx-xx (hex)