3-3 Setting the initial parameters for the spindle drive unit
【#3060】 sptc7 Spindle synchronization multi-step acceleration/deceleration changeover
speed 7
Set the spindle speed for changing the 7th step's acceleration/deceleration time constant.
---Setting range---
0 to 99999 (r/min)
【#3061】 spdiv1 Magnification for time constant changeover speed 1
Set the acceleration/deceleration time constant from the spindle synchronization multi-step
acceleration/deceleration changeover speed 1 (sptc1) to the spindle synchronization multi-step
acceleration/deceleration changeover speed 2 (sptc2). Set this as a magnification in relation to the
spindle synchronization acceleration/deceleration time constant (spt).
---Setting range---
0 to 127
【#3062】 spdiv2 Magnification for time constant changeover speed 2
Set the acceleration/deceleration time constant from the spindle synchronization multi-step
acceleration/deceleration changeover speed 2 (sptc2) to the spindle synchronization multi-step
acceleration/deceleration changeover speed 3 (sptc3). Set this as a magnification in relation to the
spindle synchronization acceleration/deceleration time constant (spt).
---Setting range---
0 to 127
【#3063】 spdiv3 Magnification for time constant changeover speed 3
Set the acceleration/deceleration time constant from the spindle synchronization multi-step
acceleration/deceleration changeover speed 3 (sptc3) to the spindle synchronization multi-step
acceleration/deceleration changeover speed 4 (sptc4). Set this as a magnification in relation to the
spindle synchronization acceleration/deceleration time constant (spt).
---Setting range---
0 to 127
【#3064】 spdiv4 Magnification for time constant changeover speed 4
Set the acceleration/deceleration time constant from the spindle synchronization multi-step
acceleration/deceleration changeover speed 4 (sptc4) to the spindle synchronization multi-step
acceleration/deceleration changeover speed 5 (sptc5). Set this as a magnification in relation to the
spindle synchronization acceleration/deceleration time constant (spt).
---Setting range---
0 to 127
【#3065】 spdiv5 Magnification for time constant changeover speed 5
Set the acceleration/deceleration time constant from the spindle synchronization multi-step
acceleration/deceleration changeover speed 5 (sptc5) to the spindle synchronization multi-step
acceleration/deceleration changeover speed 6 (sptc6). Set this as a magnification in relation to the
spindle synchronization acceleration/deceleration time constant (spt).
---Setting range---
0 to 127
【#3066】 spdiv6 Magnification for time constant changeover speed 6
Set the acceleration/deceleration time constant from the spindle synchronization multi-step
acceleration/deceleration changeover speed 6 (sptc6) to the spindle synchronization multi-step
acceleration/deceleration changeover speed 7 (sptc7). Set this as a magnification in relation to the
spindle synchronization acceleration/deceleration time constant (spt).
---Setting range---
0 to 127