![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/3/c1/3c14d478-ced0-4fee-8279-371ef1a3b7f8/3c14d478-ced0-4fee-8279-371ef1a3b7f8-bg114.png)
4 - 21
MDS-D-SVJ3/SPJ3 Series Instruction Manual
4-4 Characteristics improvement
【#2246】 SV046 FHz2 Notch filter frequency 2
Set the vibration frequency to suppress when machine vibration occurs.
(Normally, do not set 80 or less.)
Set to "0" when not using.
---Setting range---
0 to 2250 (Hz)
【#2283】 SV083 SSF6 Servo function 6
bit 7-5 : nfd5 Depth of Notch filter 5
Set the depth of Notch filter 5.
bit7,6,5=
000: - ∞
001: -18.1[dB]
010: -12.0[dB]
011: -8.5[dB]
100: -6.0[dB]
101: -4.1[dB]
110: -2.5[dB]
111: -1.2[dB]
Set the adaptive frequency of Notch filter 5 in "#2288 SV088 FHz5".
bit 3-1 : nfd4 Depth of Notch filter 4
Set the depth of Notch filter 4.
bit3,2,1=
000: - ∞
001: -18.1[dB]
010: -12.0[dB]
011: -8.5[dB]
100: -6.0[dB]
101: -4.1[dB]
110: -2.5[dB]
111: -1.2[dB]
Set the adaptive frequency of Notch filter 4 in "#2287 SV087 FHz4".
【#2287】 SV087 FHz4 Notch filter frequency 4
Set the vibration frequency to suppress when machine vibration occurs.
(Normally, do not set 80 or less.)
Set to "0" when not using.
---Setting range---
0 to 2250 (Hz)
【#2288】 SV088 FHz5 Notch filter frequency 5
Set the vibration frequency to suppress when machine vibration occurs.
(Normally, do not set 80 or less.)
Set to "0" when not using.
---Setting range---
0 to 2250 (Hz)