A SERVICE OF

logo

Appendix 2 - 26
Appendix 2 Cable and Connector Assembly
MITSUBISHI CNC
(4) Refer to Application Specification (114-5335) and crimp the contacts. After crimping, check the state in
accordance with the Specification.
(5) Verifying the direction, insert the crimped contact into the receptacle housing. After the insertion, pull
each wire lightly to make sure that the contacts are fully inserted. (Lock feeling and sound can be
confirmed when the contact is fully/correctly inserted.)
(6) Crimp the ground clip.
As receptacle housing is settled inside a ground clip, it opts for direction according to the purpose, and
positions as shown below.
(Note) Direction of receptacle housing is unchangeable after ground slip crimping.
Positioning the cable jacket end as shown below. Refer to the Application Specification (114-5338) and
crimp the ground clip.
Receptacle contact
or
1mm