Syntax: Message ID: 229
Example:
AGCMODE L1 MANUAL 40 50
Table 17: Antispoofing Flag Values
AGCMODE FREQUENCY MODE [ PULSEWIDTH LOADVALUE ]
Field
Field
Name
Valid Values
Description Format
Binary
Bytes
Binary
Offset
ASCII Binary
1 header
This field contains the Abbreviated ASCII command name. See Section 4.1
on Page 31.
H 0
2 frequency See Table 15 on Page 45.
Specifies which signal
type to apply the
command to.
Enum 4 H
3 mode See Table 16 on Page 45.
Specifies whether to
use the default or
custom values for the
pulse width and load
value.
Enum
4 H+4
4 pulsewidth 35 to 262144
Pulse width. A value is
only required when the
mode field is set to
MANUAL.
Float
4 H+8
5 loadvalue 35 to 262144
Modulus load value. A
value is only required
when the mode field is
set to MANUAL.
Float
4 H+12
ASCII Description
FALSE Antispoofing is disabled.
TRUE Antispoofing is enabled.