72 EuroPak-15a Receiver User Manual Rev 5
Chapter 6 Data Logs
6.3.1 AGCSTATS Automatic Gain Control Status
This log provides status information for the automatic gain control mechanism and details of the parameters it
is currently using.
Log Type: Synch Message ID: 630
Field
Field
Name
Data Description Format
Binary
Bytes
Binary
Offset
1 header
This field contains the message header, in ASCII or Binary format.
See Section 4.3 on Page 35.
H 0
2 # RF decks Number of RF decks reported in this message. Ulong 4 H
3 AGCword AGC status word (see Table 35 on Page 73) Ulong 4 H+4
4 gain AGC gain (0 to 99999) Ulong 4 H+8
5 pulse width VARF pulse width Ulong 4 H+12
6 modulus VARF modulus Ulong 4 H+16
7 bin1 A/D bin 1 (decimal percentage) Double 8 H+20
8 bin2 A/D bin 2 (decimal percentage) Double 8 H+28
9 bin3 A/D bin 3 (decimal percentage) Double 8 H+36
10 bin4 A/D bin 4 (decimal percentage) Double 8 H+44
11 bin5 A/D bin 5 (decimal percentage) Double 8 H+52
12 bin6 A/D bin 6 (decimal percentage) Double 8 H+60
13 noise floor Calculated noise floor Double 8 H+68
14
Reserved
Double 8 H+76
15 Double 8 H+84
16... Next RF deck, offset = H+ 4 + (#RF *88) Bytes
32-bit CRC (ASCII and Binary only) Hex 4
H+ 4
(#RF*88)