Section 8: Adjustment Procedures
SATO M10e Service Manual PN: 9001113A Page 8-10
18 Confirm that NONE is displayed and press ENTER.
19 Use the Cursor keys to step the cursor to the desired text size option.
20 Press the ENTER key to select the option and begin test printing.
21 Regard the test label critically to ensure that the print image is not skewed or off center.
22 Adjust the VR9 potentiometer as required to correct the positioning.
23 Press the ENTER key and switch off the printer.
EYE-MARK SENSOR ADJUSTMENT
This adjustment will require the use of a multimeter and the TP Test Module. The eye-mark
sensor may also be adjusted via the Service Mode.
1 Remove the top, front, and left housing cover to access main circuit board (1, Figure 8-8).
2 Turn VR5 potentiometer (2) fully counter-clockwise.
NOTE: Repeat the above steps should NONE not be displayed.
CAUTION: THIS TEST ACTIVATES ALL OF THE HEATING ELEMENTS OF
THE PRINT HEAD AND THEREFORE SHOULD ONLY BE USED FOR
TESTING PUPOSES WITH FULL WIDTH LABELS TO AVOID DAMAGING
THE PRINT HEAD.
NOTE: The ENTER key may be used to cease and resume printing activity.
NOTE: Refer to Figure 8-1 for guidance on critical analysis of the print image.
NOTE: The scale should be at the beginning of the label and evenly oriented.
The adjustment range of the VR9 potentiometer +/- 3.75mm.
NOTE: Figure 10-4, Block Diagram, Figure 10-5, Accessories & Sensors
Location; and Figure 10-6, Print Position Reference Diagram of the Diagrams
& Schematics section provide additional instruction.
NOTE: Figure 10-1 of the Diagrams & Schematics section provides guidance
on housing cover removal.
NOTE: An audible click should be heard.