Bosch Appliances D6600 Car Stereo System User Manual


 
No Data Received Reports
If a message is garbled (incorrect checksum or inconsistent message rounds) due to a noisy
telephone line or other difficulty, the receiver withholds the kiss-off tone. This causes the
control panel to send the same message again up to four times.
No Data Received
The D6600/D6100IPv6 generates one or more of the following events:
Telephone line noise causes the data to be unrecognized.
A control panel sends the data in a format not recognized by the D6600/D6100IPv6.
A control panel transmitted nothing.
Figure 13.1: No Data Received Message
Data Error
Data Error is a function of PSTN. It is an error condition when the D6600/D6100IPv6 receives
partial data, appears on the LCD, and sends the error to a connected printer.
This occurs when telephone line noise causes data to be unrecognizable.
Wrong Data
Wrong Data is a function of the CPU where the PSTN software sends an invalid signal to the
CPU. It only sends output to the LCD and any connected printer.
13
13.1
13.2
13.3
72 en | No Data Received Reports
Conettix Communications Receiver/