StorageTek D173/9176 Car Stereo System User Manual


 
Program Configuration
42 MN5002
k. 19 inch rackmount cabinet installation available
l. Height = 3U for the Disk Controller Array and each 9170 expansion unit
m. One Storage partition is supplied. Ordered separately, feature code
PT02 is for 1-2 storage partitions. P1T4 is for Storage Partition 1-4. If you
increase the number of attaches using network hardware (hubs,
switches, etc..), P5T8, Storage Partition 5-8 would be the additional
feature code ordered. A form is available with more (up to 16 (PT16)).
Note: Storage Partitioning enables sharing of the disk capacity from a single
D173 disk controller array among several hosts or host group. One
storage partition is required for every host or host group. The partition
represents a logical division of the disk that is only visible to the host or
host group to which it is assigned.
9170-001 Disk Array
This is scalable disk (drive trays) for increasing capacity and meeting growing
storage requirements.
Logical Rules Summary:
a. Maximum of 10 drives per drawer (9170 Disk Array)
b. Minimum of 5 drives and 5 filler panels (FP05)
c. Minimum of 1 storage array per 9176 Disk Controller
d. Maximum of 20 9170s per controller
e. Height = 3U
Host Interface Kits for 9176-001/002
The host interface kits (depending on the host type) contain some or all of the
following components:
Host bus adapters (interface cards), software driver, and manuals (when
applicable)
CD-ROMs - contain Firmware, Software & Manuals (documentation is
provided in Printed Document Format (PDF)
Copper or Shortwave GBIC
Fibre channel cables must be ordered separately with feature codes.
CBNT M03 - 39U FIXED HEIGHT CABINET
39U Fixed cabinet
Maximum number of U’s is 39U
9176 Disk Controller: 4U
9170 Disk Array: 3U
9176/9170 models will have rackmount rails when ordered with M03R