A SERVICE OF

logo

224
Setting the parameter unit and operation panel
4.19 Setting the parameter unit and operation panel
4.19.1 RUN key rotation direction selection (Pr. 40)
The above parameter can be set when Pr. 160 Extended function display selection = "0". (Refer to page 144)
4.19.2 PU display language selection (Pr. 145)
The above parameter can be set when Pr. 160 Extended function display selection = "0". (Refer to page 144)
Purpose Parameter that should be Set Refer to Page
Selection of rotation direction by
of the operation panel
RUN key rotation
direction selection
Pr. 40
224
Switch the display language of the
parameter unit
PU display language
selection
Pr. 145
224
Use the setting dial of the operation
panel like a potentiometer for speed
setting
Key lock of operation panel
Operation panel
operation selection
Pr. 161
225
Change the magnitude of change of
speed setting by the setting dial of
the operation panel
Magnitude of speed
change setting
Pr. 295
228
Control of the parameter unit buzzer PU buzzer control Pr. 990
229
Adjust LCD contrast of the
parameter unit
PU contrast adjustment Pr. 991
229
Used to choose the direction of rotation by operating of the operation panel.
Parameter
Number
Name Initial Value Setting Range Description
40
RUN key rotation direction
selection
0
0 Forward rotation
1
Reverse rotation
You can switch the display language of the parameter unit (FR-PU07) to another.
Parameter
Number
Name Initial Value Setting Range Description
145
PU display language
selection
0
0
Japanese
1
English
2 German
3 French
4
Spanish
5
Italian
6
Swedish
7
Finnish