Parameter listParameter list
62
4
PARAMETERS
Parameter List
—
870
Speed detection hysteresis
0 to 150r/min/
0 to 100r/min
∗1
1r/min 15r/min
110
870
46 C6 8 { { {
Protective
functions
872
Input phase loss protection selection 0, 1 1 0
128
872
48 C8 8 {{ {
Regeneration
avoidance function
882
Regeneration avoidance operation
selection
0 to 2 1 0
211
882
52 D2 8 { { {
883
Regeneration avoidance operation
level
300 to 800V 0.1V 400V
211
883
53 D3 8 {{ {
885
Regeneration avoidance compensation
speed limit value
0 to 900r/min/
0 to 600r/min
∗1, 9999
1r/min 180r/min
211
885
55 D5 8 { { {
886
Regeneration avoidance voltage gain 0 to 200% 0.1% 100%
211
886
56 D6 8 {{ {
Free
parameter
888
Free parameter 1 0 to 9999 1 9999
221
888
58 D8 8 {
× ×
889
Free parameter 2 0 to 9999 1 9999
221
889
59 D9 8 {
××
Energy
saving
monitor
891
Cumulative power monitor digit shifted
times
0 to 4, 9999 1 9999
117
891
5B DB 8 { { {
Calibration parameters
C0
(900) ∗2
FM terminal calibration — — —
123
C0
(900)
5C DC 1 {
×
{
C2
(902) ∗2
Terminal 2 speed setting bias speed
0 to 12000r/min/
0 to 8000r/min
∗1
1r/min 0r/min
135
C2
(902)
5E DE 1 {
×
{
C3
(902) ∗2
Terminal 2 speed setting bias 0 to 300% 0.1% 0%
135
C3
(902)
5E DE 1 {
×
{
125
(903) ∗2
Terminal 2 speed setting gain speed
0 to 12000r/min/
0 to 8000r/min
∗1
1r/min 3000r/min
135
125
(903)
5F DF 1 {
×
{
C4
(903) ∗2
Terminal 2 speed setting gain 0 to 300% 0.1% 100%
135
C4
(903)
5F DF 1 {
×
{
C5
(904) ∗2
Terminal 4 speed setting bias speed
0 to 12000r/min/
0 to 8000r/min
∗1
1r/min 0r/min
135
C5
(904)
60 E0 1 {
×
{
C6
(904) ∗2
Terminal 4 speed setting bias 0 to 300% 0.1% 20%
135
C6
(904)
60 E0 1 {
×
{
126
(905) ∗2
Terminal 4 speed setting gain speed
0 to 12000r/min/
0 to 8000r/min
∗1
1r/min 3000r/min
135
126
(905)
61 E1 1 {
×
{
C7
(905) ∗2
Terminal 4 speed setting gain 0 to 300% 0.1% 100%
135
C7
(905)
61 E1 1 {
×
{
PID control
C42
(934) ∗2
PID display bias coefficient 0 to 500, 9999 0.01
9999
199
C42
(934)
22 A2 9 {
×
{
C43
(934) ∗2
PID display bias analog value 0 to 300% 0.1%
20%
199
C43
(934)
22 A2 9 {
×
{
C44
(935) ∗2
PID display gain coefficient 0 to 500, 9999 0.01
9999
199
C44
(935)
23 A3 9 {
×
{
C45
(935) ∗2
PID display gain analog value 0 to 300% 0.1%
100%
199
C45
(935)
23 A3 9 {
×
{
PU
990
PU buzzer control 0, 1 1 1
229
990
5A DA 9 { { {
991
PU contrast adjustment 0 to 63 1 58
229
991
5B DB 9 {
×
{
—
997
Fault initiation
16 to 18, 32 to 34, 48,
49, 64, 82, 96, 97, 112,
128, 129, 144, 145, 176
to 178, 192, 196, 197,
199, 201, 208, 230, 245,
9999
1 9999
221
997
61 E1 9
× × ×
—
999
Automatic parameter setting 10, 9999 1 9999
222
999
63 E3 9
×× ×
Function
Parameter
Name Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Parameter Remarks
Instruction Code Parameter
Read Write
Extended