![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/b/24/b249deaf-1fd7-4d91-a629-3b60b4c6e920/b249deaf-1fd7-4d91-a629-3b60b4c6e920-bg3d.png)
Parameter listParameter list
52
4
PARAMETERS
Parameter List
4.2 Parameter list
4.2.1 parameter list
For simple variable-speed operation of the drive unit, the initial setting of the parameters may be used. Set the necessary
parameters to meet the load and operational specifications. Parameter setting, change and check can be made from the
operation panel.
y These instruction codes are used for parameter read and write by using Mitsubishi inverter protocol with the RS-485 communication.
(Refer to page 167 for RS-485 communication)
y "{" indicates valid and "×" indicates invalid of "control mode-based correspondence table", "parameter copy", "parameter clear", and "all parameter clear".
Function
Parameter
Name Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Parameter Remarks
Instruction Code Parameter
Read Write
Extended
Copy Clear All clear
Basic functions
1
Maximum setting
0 to 12000r/min/
0 to 8000r/min
∗1
1r/min 3000r/min
78
1
01 81 0 {{ {
2
Minimum setting
0 to 3600r/min/
0 to 2400r/min
∗1
1r/min 0r/min
78
2
02 82 0 { { {
4
Multi-speed setting (high speed)
0 to 12000r/min/
0 to 8000r/min
∗1
1r/min 3000r/min
80
4
04 84 0 {{ {
5
Multi-speed setting (middle speed)
0 to 12000r/min/
0 to 8000r/min
∗1
1r/min 1500r/min
80
5
05 85 0 { { {
6
Multi-speed setting (low speed)
0 to 12000r/min/
0 to 8000r/min
∗1
1r/min 300r/min
80
6
06 86 0 {{ {
7
Acceleration time 0 to 3600s 0.1s 5s
87
7
07 87 0 { { {
8
Deceleration time 0 to 3600s 0.1s 5s
87
8
08 88 0 {{ {
9
Electronic thermal O/L relay 0 to 500A 0.01A
Rated motor
current
91
9
09 89 0 { { {
DC injection
brake
10
Coasting speed
0 to 3600r/min/
0 to 2400r/min
∗1
1r/min 90r/min
94
10
0A 8A 0 {{ {
11
DC injection brake operation time 0 to 10s 0.1s 0.5s
94
11
0B 8B 0 { { {
—
13
Starting speed
0 to 1800r/min/
0 to 1200r/min
∗1
1r/min 15r/min
89
13
0D 8D 0 {{ {
JOG
operation
15
Jog speed setting
0 to 12000r/min/
0 to 8000r/min
∗1
1r/min 150r/min
82
15
0F 8F 0 { { {
16
Jog acceleration/deceleration time 0 to 3600s 0.1s 0.5s
82
16
10 90 0 {{ {
—
17
MRS input selection 0, 2, 4 1 0
102
17
11 91 0 { { {
Acceleration/
deceleration time
20
Acceleration/deceleration reference
speed
30 to 12000r/min/
20 to 8000r/min
∗1
1r/min 3000r/min
87
20
14 94 0 {{ {
Stall
prevention
22
Stall prevention operation level 0 to 200% 0.1% 150%
74
22
16 96 0 { { {
Multi-speed
setting
24
Multi-speed setting (speed 4)
0 to 12000r/min/
0 to 8000r/min
∗1, 9999
1r/min 9999
80
24
18 98 0 {{ {
25
Multi-speed setting (speed 5)
0 to 12000r/min/
0 to 8000r/min
∗1, 9999
1r/min 9999
80
25
19 99 0 { { {
26
Multi-speed setting (speed 6)
0 to 12000r/min/
0 to 8000r/min
∗1, 9999
1r/min 9999
80
26
1A 9A 0 {{ {
27
Multi-speed setting (speed 7)
0 to 12000r/min/
0 to 8000r/min
∗1, 9999
1r/min 9999
80
27
1B 9B 0 { { {
Parameter Name
Initial Value Setting Range
Remarks
160
Extended function display
selection
9999
9999 Displays only the simple mode parameters
0 Displays simple mode + extended parameters
REMARKS
y indicates simple mode parameters.
y The parameters surrounded by a black border in the table allow its setting to be changed during operation even if "0" (initial
value) is set in Pr. 77 Parameter write selection.