A SERVICE OF

logo

83
Speed setting by external terminals
4
PARAMETERS
(2) Jog operation from PU
Select Jog operation mode from the operation panel and the parameter unit (FR-PU07). Operation is performed only while
the start button is pressed.
Operation Display
1.
Confirmation of the operating status indicator
and operation mode indicator
The monitor mode should have been
selected.
The drive unit should be at a stop.
2. Press to choose the PU Jog operation
mode.
3. Press .
While is pressed, the motor rotates.
The motor runs at 150r/min. (Pr. 15 initial
value)
Press
4. Release
Release
[When changing the speed of PU Jog operation]
5. Press to choose the parameter setting
mode.
PRM indicator is lit.
(The parameter number read previously
appears.)
6. Turn until Pr. 15 Jog speed setting appears.
7. Press to show the present set value.
(150r/min)
8. Turn to set the value to " ".
(300r/min)
9. Press to set.
Flicker...Parameter setting complete!!
10.Perform the operations in steps 1 to 4.
The motor rotates at 300r/min.
Three-phase AC
power supply
Drive unit
R/L1
S/L2
T/L3
U
V
W
Operation panel
Motor
Stop