![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/b/24/b249deaf-1fd7-4d91-a629-3b60b4c6e920/b249deaf-1fd7-4d91-a629-3b60b4c6e920-bg4e.png)
76
Adjustment of the output torque (current) of the motor
(5) Limit the stall prevention operation according to the operating status (Pr. 156)
Refer to the following table and select whether stall prevention operation will be performed or not and the operation to be
performed at OL signal output.
∗1
When "Operation not continued for OL signal output" is selected, the fault (stopped by stall prevention) is displayed and operation is stopped.
∗2 Since stall prevention is not activated, OL signal and E.OLT are not output.
∗3 The settings "100" and "101" allow operations to be performed in the driving and regeneration modes, respectively.
Pr. 156
Setting
Stall Prevention Operation
Selection
: Activated
:
Not activated
OL Signal Output
:
Operation
continued
:
Operation not
continued
∗1
Pr. 156
Setting
Stall Prevention Operation
Selection
: Activated
:
Not activated
OL Signal Output
:
Operation
continued
:
Operation not
continued
∗1
Acceleration
Constant
speed
Deceleration
Acceleration
Constant
speed
Deceleration
0
(initial value),
1
16
,
17
2
,
3 18
,
19
4
,
5
20
,
21
6
,
7
22
,
23
8
,
9
24
,
25
10
,
11
26
,
27
12
,
13 28
,
29
14
,
15 — ∗2 30
,
31 — ∗2
100,
101
∗3
Power driving
Regeneration
∗2
NOTE
When the load is heavy or the acceleration/deceleration time is short, stall prevention is activated and acceleration/
deceleration may not be made according to the preset acceleration/deceleration time. Set Pr. 156
and stall prevention
operation level to the optimum values.
CAUTION
Do not set a small value as the stall prevention operation current.
Otherwise, torque generated will reduce.
Test operation must be performed.
Stall prevention operation during acceleration may increase the acceleration time.
Stall prevention operation performed during constant speed may cause sudden speed changes.
Stall prevention operation during deceleration may increase the deceleration time, increasing the deceleration
distance.
Parameters referred to
Pr. 178 to Pr. 182 (input terminal function selection) Refer to page 100
Pr. 190, Pr. 192 (output terminal function selection) Refer to page 106