Parameter listParameter list
56
4
PARAMETERS
Parameter List
PU connector communication
117
PU communication station number 0 to 31 (0 to 247) 1 0
167
,
186
117
11 91 1 {{ ∗4 { ∗4
118
PU communication speed 48, 96, 192, 384 1 192
167
,
186
118
12 92 1 { { ∗4 { ∗4
119
PU communication stop bit length 0, 1, 10, 11 1 1
167
119
13 93 1 {{ ∗4 { ∗4
120
PU communication parity check 0 to 2 1 2
167
,
186
120
14 94 1 { { ∗4 { ∗4
121
Number of PU communication retries 0 to 10, 9999 1 1
168
121
15 95 1 {{ ∗4 { ∗4
122
PU communication check time interval 0, 0.1 to 999.8s, 9999 0.1s 0
168
,
186
122
16 96 1 { { ∗4 { ∗4
123
PU communication waiting time setting 0 to 150ms, 9999 1 9999
167
123
17 97 1 {{ ∗4 { ∗4
124
PU communication CR/LF selection 0 to 2 1 1
167
124
18 98 1 { { ∗4 { ∗4
125
Terminal 2 speed setting gain speed
0 to 12000r/min/
0 to 8000r/min
∗1
1r/min 3000r/min
135
125
19 99 1 {
×
{
126
Terminal 4 speed setting gain speed
0 to 12000r/min/
0 to 8000r/min
∗1
1r/min 3000r/min
135
126
1A 9A 1 {
×
{
PID operation
127
PID control automatic switchover
speed
0 to 12000r/min/
0 to 8000r/min
∗1, 9999
1r/min 9999
199
127
1B 9B 1 {{ {
128
PID action selection 0, 20, 21 1 0
199
128
1C 9C 1 { { {
129
PID proportional band 0.1 to 1000%, 9999 0.1% 100%
199
129
1D 9D 1 {{ {
130
PID integral time 0.1 to 3600s, 9999 0.1s 1s
199
130
1E 9E 1 { { {
131
PID upper limit 0 to 100%, 9999 0.1% 9999
199
131
1F 9F 1 {{ {
132
PID lower limit 0 to 100%, 9999 0.1% 9999
199
132
20 A0 1 { { {
133
PID action set point 0 to 100%, 9999 0.01% 9999
199
133
21 A1 1 {{ {
134
PID differential time 0.01 to 10s, 9999 0.01s 9999
199
134
22 A2 1 { { {
144
Speed setting switchover
2, 4, 6, 8, 10, 102, 104,
106, 108, 110
1 104/106 ∗1
115
144
2C AC 1 {{ {
PU
145
PU display language selection 0 to 7 1 0
224
145
2D AD 1 {
× ×
Current
detection
150
Output current detection level 0 to 200% 0.1% 150%
111
150
32 B2 1 {{ {
151
Output current detection signal delay
time
0 to 10s 0.1s 0s
111
151
33 B3 1 { { {
152
Zero current detection level 0 to 200% 0.1% 5%
111
152
34 B4 1 {{ {
153
Zero current detection time 0 to 1s 0.01s 0.5s
111
153
35 B5 1 { { {
156
Stall prevention operation selection 0 to 31, 100, 101 1 0
74
156
38 B8 1 {{ {
157
OL signal output timer 0 to 25s, 9999 0.1s 0s
74
157
39 B9 1 { { {
160
Extended function display selection 0, 9999 1 9999
144
160
00 80 2 {{ {
161
Speed setting/key lock operation
selection
0, 1, 10, 11 1 0
225
161
01 81 2 {
×
{
Current
detection
166
Output current detection signal
retention time
0 to 10s, 9999 0.1s 0.1s
111
166
06 86 2 {{ {
167
Output current detection operation
selection
0, 1 1 0
111
167
07 87 2 { { {
168
Parameter for manufacturer setting. Do not set.
168
Parameter for manufacturer setting. Do not set.
169 169
Cumulative
monitor clear
170
Watt-hour meter clear 0, 10, 9999 1 9999
117
170
0A 8A 2 {
×
{
171
Operation hour meter clear 0, 9999 1 9999
117
171
0B 8B 2
× × ×
Input terminal function
selection
178
STF terminal function selection
0 to 5, 7, 8, 10, 12, 14,
16, 23 to 25, 60, 62, 64
to 67, 72, 9999
160
100
178
12 92 2 {
×
{
179
STR terminal function selection
0 to 5, 7, 8, 10, 12, 14,
16, 23 to 25, 61, 62, 64
to 67, 72, 9999
1 61
100
179
13 93 2 {
×
{
180
RL terminal function selection
0 to 5, 7, 8, 10, 12, 14,
16, 23 to 25, 62, 64 to
67, 72, 9999
10
100
180
14 94 2 {
×
{
181
RM terminal function selection 1 1
100
181
15 95 2 {
×
{
182
RH terminal function selection 1 2
100
182
16 96 2 {
×
{
Function
Parameter
Name Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Parameter Remarks
Instruction Code Parameter
Read Write
Extended
Copy Clear All clear