Parameter listParameter list
60
4
PARAMETERS
Parameter List
RS-485
communication
338
Communication operation command
source
0, 1 1 0
160
338
26 A6 3 { { ∗4 { ∗4
339
Communication speed command
source
0 to 2 1 0
160
339
27 A7 3 {{ ∗4 { ∗4
340
Communication startup mode selection 0, 1, 10 1 0
159
340
28 A8 3 { { ∗4 { ∗4
342
Communication EEPROM write
selection
0, 1 1 0
173
342
2A AA 3 {{ {
343
Communication error count 1 0
186
343
2B AB 3
× × ×
374
Overspeed detection level
0 to 12000r/min/
0 to 8000r/min
∗1
1r/min 3450r/min
129
374
4A CA 3 {{ {
Remote
Output
495
Remote output selection 0, 1, 10, 11 1 0
113
495
5F DF 4 { { {
496
Remote output data 1 0 to 4095 1 0
113
496
60 E0 4
×× ×
502
Stop mode selection at communication
error
0 to 3 1 0
168,
186
502
02 82 5 { { {
Maintenance
503
Maintenance timer 0 (1 to 9998) 1 0
218
503
03 83 5
×× ×
504
Maintenance timer alarm output set
time
0 to 9998, 9999 1 9999
218
504
04 84 5 {
×
{
505
Speed setting reference 1 to 200Hz 0.01Hz
100Hz/
150Hz
∗1
115
505
05 85 5 {{ {
Communication
549
Protocol selection 0, 1 1 0
167
549
31 B1 5 { { ∗4 { ∗4
551
PU mode operation command source
selection
2, 4, 9999 1 9999
160
551
33 B3 5 {{ ∗4 { ∗4
PID
control
553
PID deviation limit 0 to 100%, 9999 0.1% 9999
199
553
35 B5 5 { { {
554
PID signal operation selection 0 to 3, 10 to 13 1 0
199
554
36 B6 5 {{ {
Current
average
monitor
555
Current average time 0.1 to 1s 0.1s 1s
219
555
37 B7 5 { { {
556
Data output mask time 0 to 20s 0.1s 0s
219
556
38 B8 5 {{ {
557
Current average value monitor signal
output reference current
0 to 500A 0.01A
Rated motor
current
219
557
39 B9 5 { { {
561
PTC thermistor protection level 0.5 to 30kΩ, 9999 0.01kΩ 9999
91
561
3D BD 5 {
×
{
563
Energization time carrying-over times (0 to 65535) 1 0
117
563
3F BF 5
× × ×
564
Operating time carrying-over times (0 to 65535) 1 0
117
564
40 C0 5
×× ×
PID
control
575
Output interruption detection time 0 to 3600s, 9999 0.1s 1s
199
575
4B CB 5 { { {
576
Output interruption detection level
0 to 12000r/min/
0 to 8000r/min
∗1
1r/min 0r/min
199
576
4C CC 5 {{ {
577
Output interruption cancel level 900 to 1100% 0.1% 1000%
199
577
4D CD 5 { { {
665
Regeneration avoidance speed gain 0 to 200% 0.1% 100%
211
665
41 C1 6 {{ {
736
Electromagnetic brake interlock time 0 to 1s 0.01s 0.00s
96
736
56 D6 7 { { {
779
Operation speed during
communication error
0 to 12000/min/
0 to 8000r/min
∗1, 9999
1r/min 9999
186
779
4F CF 7 {{ {
785
PM control torque boost 0 to 150%, 9999 0.1% 9999
77
785
55 D5 7 { { {
Acceleration/
deceleration
time
791
Acceleration time in low-speed range 0 to 3600s, 9999 0.1s 9999
87
791
5B DB 7 {{ {
792
Deceleration time in low-speed range 0 to 3600s, 9999 0.1s 9999
87
792
5C DC 7 { { {
795
DC brake torque boost 0 to 150%, 9999 0.1% 9999
94
795
5F DF 7 {{ {
799
Pulse increment setting for output
power
0.1kWh, 1kWh, 10kWh,
100kWh, 1000kWh
0.1kWh 1kWh
114
799
63 E3 7 { { {
800
Control method selection 9, 30 1 30
69
800
00 80 8 {{ {
Adjustment
function
820
Speed control P gain 0 to 1000% 1% 15%
71
820
14 94 8 { { {
821
Speed control integral time 0 to 20s 0.001s 0.333s
71
821
15 95 8 {{ {
Function
Parameter
Name Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Parameter Remarks
Instruction Code Parameter
Read Write
Extended
Copy Clear All clear