Sharp PN-60TA3 Car Video System User Manual


 
62
E
Commands for setting of the GAMMA user data
Function
Command Direction
Parameter Reply Control/Response contents
RED GAMMA DATA TRANSFER UGRW W aaxxxx
···
xxxxcc
(xxxx: 32 pieces)
aa: 01-16
xxxx: 0000-1023
cc: 00-FF
aa: Block number
xxxx: 32 pieces of user data
cc: Checksum (ASCII data) of the block number and user data
GREEN GAMMA DATA TRANSFER UGGW W
BLUE GAMMA DATA TRANSFER UGBW W
RED GAMMA DATA READ UGRR W 1-16 xxxx
···
xxxx
(xxxx: 32 pieces)
xxxx: 0000-1023
xxxx: User data of 32 pieces
GREEN GAMMA DATA READ UGGR W 1-16
BLUE GAMMA DATA READ UGBR W 1-16
USER DATA INITIALIZE UGRS W 0 Initialize the user data.
USER DATA SAVE UGSV W 0 Save the user data in the monitor.
To transfer the GAMMA user data
Use the user data transfer commands (UGRW, UGGW and UGBW). For each of the R, G and B colors, divide the total 512
pieces of user data into 16 blocks, and transfer 32 pieces of data with each command.
C1 C2 C3 C4 P1 P2 P3 P4
S1 S2
Command field
Block number (01 to 16)
Data fieldChecksum field
Example: To transfer the data of block 1 (0 to 31 levels)
of red (R) data
UGRW01000000010002 … 0031C0
Command
Block number
32 pieces of data Checksum
One piece of data consists
of 4 digits.
* If data is less than 4 digits, add a “0” (zero) to make it 4 digits.
* The checksum eld is the character string (ASCII) data of lower-order one byte which indicates the sum of the block number
and 32 pieces of data in hexadecimal (0 to F).
Saving the GAMMA user data
Use the user data save command (UGSV) to save the transferred user data in the monitor.
If the data is not saved, it will be cleared when:
The main power switch is off
STANDBY MODE is LOW POWER and the monitor enters standby mode
Activating the GAMMA user data
To activate the transferred user data, select USER for GAMMA in the PICTURE menu, or send the corresponding control
command.
Checking the GAMMA user data
Use the user data read commands (UGRR, UGGR and UGBR) to return 512 pieces of user data for each of the R, G and B
colors. Divide the data into 16 blocks and return 32 pieces of data with each command. The value to be returned is not the value
stored in the monitor, but the value in the temporary memory for display. (These values are the same when the user data save
command (UGSV) above has been sent.)
TIPS
The user data is not initialized by RESET of the PICTURE menu. To initialize the user data, use ALL RESET of the
FUNCTION menu.
The GAMMA user data initialize command (UGRS) allows the initialization of the user data only.
Controlling the Monitor with a PC (LAN)