Product Specications
Model PN-70TA3 PN-60TA3
LCD component
70" Class [69-1/2 inch (176.6cm)
diagonal] TFT LCD
60" Class [60-1/16 inch (152.5cm)
diagonal] TFT LCD
Max. resolution (pixels)
1920 x 1080
Max. colors
Approx. 1.06 billion colors
Pixel pitch
0.802 mm (H) × 0.802 mm (V) 0.692 mm (H) × 0.692 mm (V)
Viewing angle
160° right/left/up/down (contrast ratio ≥ 10)
Screen active area inch (mm)
60-9/16 (W) x 34-1/16 (H)
(1538.9 x 865.6)
52-5/16 (W) x 29-7/16 (H)
(1329.1 x 747.6)
Computer input signal
Analog RGB (0.7 Vp-p) [75
Ω
], DisplayPort 1.1a
Sync signal
Horizontal/vertical separate (TTL: positive/negative), Sync-on-green
*1
,
Composite sync (TTL: positive/negative)
*1
Video color system
NTSC (3.58MHz)/NTSC (4.43MHz)/PAL/PAL-60/SECAM
Plug and play
VESA DDC2B
Power management
VESA DPMS
Input terminals
PC/AV HDMI x 3
PC Mini D-sub 15 pin, 3 rows x 2
DisplayPort x 1
Audio
3.5 mm mini stereo jack x 2
Output terminals
Video/Audio
DisplayPort x 1
Audio
3.5 mm mini stereo jack x 1
LAN terminal 10 BASE-T/100 BASE-TX
Speaker output (internal/external) 10 W + 10 W/10 W + 10 W
6
Ω
Touch Panel
Detection method Infrared blocking detection method
PC connector USB (2.0 compliant) (Type B) x 2
Touch pen Wireless communication method
(2.4 GHz, IEEE 802.15.4 compliant, DS-SS method)
Touch pen adapter port
USB (2.0 compliant) (Type A)
WHITEBOARD
mode
LAN terminal 10 BASE-T/100 BASE-TX/1000 BASE-T
USB port USB (2.0 compliant) (Type A) x 4
Power requirement AC 100 V - 240 V, 3.0 A, 50/60 Hz AC 100 V - 240 V, 2.5 A, 50/60 Hz
Operating temperature
*
2
*
3
41°F to 95°F (5°C to 35°C)
Operating humidity
*
3
20% to 80% (no condensation)
Power consumption
(Maximum / input signal waiting mode
*
4
/
whiteboard standby mode / standby mode
*
5
)
250 W / 35 W / 9 W / 3.5 W 210 W / 35 W / 9 W / 3.5 W
Dimensions (excluding protrusions) inch (mm)
Approx. 64-13/16 (W) x 3-11/16 (D)
x 39-3/4 (H) (1647 x 94 x 1010)
Approx. 56-9/16 (W) x 3-11/16 (D)
x 35-1/16 (H) (1437 x 94 x 890)
Weight lbs. (kg)
Approx. 134.5 (61) Approx. 105.9 (48)
*1 D-sub input terminal only.
*2 Temperature condition may change when using the monitor together with the optional equipments recommended by SHARP.
In such cases, please check the temperature condition specied by the optional equipments.
*3 In addition, check the requirements of the computer and other devices to be connected, and make sure that all requirements are satised.
*4 When CONNECT AUTO INPUT SELECT and NO SIGNAL AUTO INPUT SEL. are set to OFF.
*5 When STANDBY MODE is set to STANDARD. When STANDBY MODE is set to LOW POWER: 0.5 W
As a part of our policy of continuous improvement, SHARP reserves the right to make design and specication changes for product improvement
without prior notice. The performance specication gures indicated are nominal values of production units. There may be some deviations from
these values in individual units.