Technical Specification
Reference Guide: TT128x High Definition Professional Receiver/Decoder Page B-21
ST.RE.E10141.5
B.7 Power Supply
B.7.1 AC Mains Input
This equipment is fitted with a wide-ranging power supply. It is suitable for
supply voltages of 100-120 Vac -10% +6% or 220-240 Vac -10% +6% at
50/60 Hz nominal.
Table B.32: AC Power Supply Specification
Item Specification
Power distribution system
Type TN ONLY (EN 60950 para 1.2.12.1): Power distribution system having one point
directly earthed, the exposed conductive parts of the installation being connected to
that point by protective earth conductors. This equipment must NOT be used with
single-phase three-wire and PE, TT or IT Type Power distribution systems.
Connection to supply Pluggable Equipment Type A (EN 60950 para 1.2.5): Equipment which is intended for
connection to the building power supply wiring via a non-industrial plug and
socket-outlet or a non-industrial appliance Coupler or both. Correct mains polarity
must always be observed. Do not use reversible plugs with this equipment.
Class of equipment Class I Equipment (EN 60950 para 1.2.4): electric shock protection by basic
insulation and protective earth.
Rated voltage 100-120/220-240 Vac
(single phase)
Rated frequency 50/60 Hz
Voltage selection Wide-ranging
Rated current 1.5 A (100-240 Vac range)
Input connector CEE 22/IEC 3-pin male receptacle
Fuse Fuse in live conductor in power input filter at rear of unit. Do not use reversible plugs
with this equipment.
Fuse type
Bussmann S505
Littelfuse 215
5x20 mm time delay (T) 1500 A breaking capacity (HBC)
IEC/EN 60127-2 Sheet 5
Fuse current rating 2 A 250 V T HBC
Power consumption
45 W typical (NO options fitted)