Texas Instruments TMS320 Car Stereo System User Manual


 
High-level input voltage
Low-level input voltageV
IL
V
IH
TMS32020
SPRS010B — MAY 1987 — REVISED NOVEMBER 1990
POST OFFICE BOX 1443 HOUSTON, TEXAS 77001
21
absolute maximum ratings over specified temperature range (unless otherwise noted)†
Supply voltage range, V
CC
– 0.3 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range – 0.3 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage range – 0.3 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous power dissipation 2 W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range – 55°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only, and
functional operation of the device at these or any other conditions beyond those indicated in the “Recommended Operating Conditions” section of
this specification is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
All voltage values are with respect to V
SS
.
recommended operating conditions
MIN NOM MAX UNIT
V
CC
Supply voltage 4.75 5 5.25 V
V
SS
Supply voltage 0 V
All inputs except CLKIN 2 V
CC
+ 0.3 V
CLKIN 2.4 V
CC
+ 0.3 V
All inputs except CLKIN – 0.3 0.8 V
CLKIN – 0.3 0.8 V
I
OH
High-level output current 300 µA
I
OL
Low-level output current 2 mA
T
A
Operating free-air temperature (see Notes 1 and 2) 0 70 °C
NOTES: 1. Case temperature (T
C
) must be maintained below 90°C.
2. R
θJA
= 36°C/Watt, R
θJC
= 6°C/Watt.
electrical characteristics over specified free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP
§
MAX UNIT
V
OH
High-level output voltage V
CC
= MIN, I
OH
= MAX 2.4 3 V
V
OL
Low-level output voltage V
CC
= MIN, I
OL
= MAX 0.3 0.6 V
I
Z
Three-state current V
CC
= MAX –20 20 µA
I
I
Input current V
I
= V
SS
to V
CC
–10 10 µA
T
A
= 0°C, V
CC
= MAX, f
x
= MAX 360 mA
I
CC
Supply current T
A
= 25°C, V
CC
= MAX, f
x
= MAX 250 mA
T
C
= 90°C, V
CC
= MAX, f
x
= MAX 285 mA
C
I
Input capacitance 15 pF
C
O
Output capacitance 15 pF
§
All typical values for I
CC
are at V
CC
= 5 V, T
A
= 25°C.
This device contains circuits to protect its inputs and outputs against damage due to high static voltages or electrostatic fields. These
circuits have been qualified to protect this device against electrostatic discharges (ESD) of up to 2 kV according to MIL-STD-883C,
Method 3015; however, it is advised that precautions should be taken to avoid application of any voltage higher than maximum-rated
voltages to these high-impedance circuits. During storage or handling, the device leads should be shorted together or the device
should be placed in conductive foam. In a circuit, unused inputs should always be connected to an appropriated logic voltage level, preferably either
V
CC
or ground. Specific guidelines for handling devices of this type are contained in the publication
Guidelines for Handling
Electrostatic-Discharge-Sensitive (ESDS) Devices and Assemblies
available from Texas Instruments.
ADVANCE INFORMATION