Texas Instruments TMS320 Car Stereo System User Manual


 
TMS320C25, TMS320E25
SPRS010B — MAY 1987 — REVISED NOVEMBER 1990
POST OFFICE BOX 1443 HOUSTON, TEXAS 77001
30
0.80 V
0.92 V
1.88 V
2.0 V
0
V
IH
(Min)
V
IL
(Max)
(a) Input
0.6 V
0.8 V
2.2 V
2.4 V
0
V
OH
(Min)
V
OL
(Max)
(b) Output
Figure 5. Voltage Reference Levels
MEMORY AND PERIPHERAL INTERFACE TIMING
switching characteristics over recommended operating conditions (see Note 3)
PARAMETER MIN TYP MAX UNIT
t
d(C1-S)
STRB from CLKOUT1 (if STRB is present) Q – 6 Q Q + 6 ns
t
d(C2-S)
CLKOUT2 to STRB (if STRB is present) – 6 0 6 ns
t
su(A)
Address setup time before STRB low (see Note 5) Q – 12 ns
t
h(A)
Address hold time after STRB high (see Note 5) Q – 8 ns
t
w(SL)
STRB low pulse duration (no wait states, see Note 6) 2Q – 5 2Q + 5 ns
t
w(SH)
STRB high pulse duration (between consecutive cycles, see Note 6) 2Q – 5 2Q + 5 ns
t
su(D)W
Data write setup time before STRB high (no wait states) 2Q – 20 ns
t
h(D)W
Data write hold time from STRB high Q – 10 Q ns
t
en(D)
Data bus starts being driven after STRB low (write cycle) 0
ns
t
dis(D)
Data bus three-state after STRB high (write cycle) Q Q+15
ns
t
d(MSC)
MSC valid from CLKOUT1 – 12 0 12 ns
Value derived from characterization data and not tested.
NOTES: 3. Q = 1/4t
c(C)
.
5. A15-A0, PS
, DS, IS, R/W, and BR timings are all included in timings referenced as “address”.
6. Delays between CLKOUT1/CLKOUT2 edges and STRB
edges track each other, resulting in t
w(SL)
and t
w(SH)
being 2Q with no wait
states.
timing requirements over recommended operating conditions (see Note 3)
MIN NOM MAX UNIT
t
a(A)
Read data access time from address time (read cycle, see Notes 5 and 7) 3Q – 35 ns
t
su(D)R
Data read setup time before STRB high 23 ns
t
h(D)R
Data read hold time from STRB high 0 ns
t
d(SL-R)
READY valid after STRB low (no wait states) Q – 20 ns
t
d(C2H-R)
READY valid after CLKOUT2 high Q – 20 ns
t
h(SL-R)
READY hold time after STRB low (no wait states) Q + 3 ns
t
h(C2H-R)
READY hold after CLKOUT2 high Q + 3 ns
t
d(M-R)
READY valid after MSC valid 2Q – 25 ns
t
h(M-R)
READY hold time after MSC valid 0 ns
NOTES: 3. Q = 1/4t
c(C)
.
5. A15-A0, PS
, DS, IS, R/W, and BR timings are all included in timings referenced as “address”.
7. Read data access time is defines as t
a(A)
= t
su(A)
+ t
w(SL)
– t
su(D)R
.
ADVANCE INFORMATION