Upgrading MVP Firmware
41
MVP-7500/8400 Modero Viewpoint Wireless Touch Panels
4. Click on the NetLinx Master radio button (from the Platform Selection section) to indicate that you are working as
a NetLinx Master.
5. Click on the Virtual Master radio box (from the Transport Connection Option section) to indicate you are wanting
to configure the PC to communicate directly with a panel. Everything else such as the Authentication is greyed-out
because you are not going through the Master’s UI.
6. Click the Edit Settings button (on the Communications Settings dialog) to open the Virtual NetLinx Master Settings
dialog (FIG. 36).
7. From within this dialog enter the System number (default is 1).
8. Click OK three times to close the open dialogs, save your settings, and return to the main NetLinx Studio
application.
9. Click the OnLine Tree tab in the Workspace window to view the devices on the Virtual System.
The default System value is one.
10. Right-click on the Empty Device Tree/System entry and select Refresh System to re-populate the list.
The panel will not appear as a device below the virtual system number (in the Online Tree tab) until both the
system number used in step 7 for the VNM is entered into the Master Connection section of the System Settings
page and the panel is restarted.
Step 3: Confirm and Upgrade the firmware via the USB port
Use the CC-USB Type-A to Mini-B 5-wire programming cable (FG10-5965) to provide communication between the
mini-USB Program port on the touch panel and the PC. This method of communication is used to transfer firmware Kit
files and TPD4 touch panel files.
1. Verify this direct USB connection (Type-A on the panel to mini-USB on the panel) is configured properly using the
steps outlined in the previous two sections.
2. With the panel already configured for USB communication and the Virtual Master setup within NetLinx Studio, its
now time to verify the panel is ready to receive files.
3. After the Communication Verification dialog window verifies active communication between the Virtual Master
and the panel, click the OnLine Tree tab in the Workspace window (FIG. 37) to view the devices on the Virtual
System. The default System value is one.
4. Right-click on the System entry (FIG. 37) and select Refresh System to re-populate the list. Verify the panel
appears in the OnLine Tree tab of the Workspace window.
The default Modero panel value is 10001.
A mini-USB connection is only detected after it is installed onto an active panel.
Connection to a previously powered panel which then reboots, allows the PC to
detect the panel and assign an appropriate USB driver.
FIG. 37 NetLinx Workspace window (showing panel connection via a Virtual NetLinx Master)
Showing the Virtual Master
firmware version and
device number
Showing the current MVP
panel firmware version and
device number
Shows NetLinx Studio
version number