AMX MVP-7500/8400 Car Video System User Manual


 
Setup Pages
53
MVP-7500/8400 Modero Viewpoint Wireless Touch Panels
Security Settings
The Security button on the Protected Setup page has three settings: Standard Security, Secure, and DoD. Each setting
has different features for touch panel security:
Toggling between these three immediately and automatically resets the existing password to the default password for that
setting. With an unsecured panel using the Standard Security setting, the default password is 1988. With panels using
either the Secure or the DoD settings, the default password is Amx1234! (paying attention to the case of the letters).
Entering the existing password will not work and the default will need to be entered at this point will allow access to the
Protected Settings page and allow resetting of the password to a new one.
For more information on configuring AMX devices for a secure environment, please refer to the guide Security Profiles:
Configuring AMX Devices For Installation Into a Secure Environment, available at www.amx.com.
Security Profile Features
Standard Security: Factory default, shipped in this configuration.
Default Protected Setup Password is “1988”.
Remote login uses Telnet.
Secure: Default Protected Setup Password is “Amx1234!”.
Minimum password requirement is 8 characters with at least one numeric character.
Remote login uses SSH.
Remote login user name is “amx”.
Login failure attempt pauses 4 seconds before another login attempt is allowed.
After 3 consecutive unsuccessful SSH login attempts, login lockout is enabled for 15
minutes.
Login and logout audit logging is enabled.
DOD: Default Protected Setup Password is “Amx1234!”.
Minimum password requirement is 8 characters with at least one numeric character,
one uppercase character, one lower case character, and one special character, with
no duplicate adjacent characters.
Remote login uses SSH.
Remote login user name is “amx”.
Login failure attempt pauses 4 seconds before another login attempt is allowed.
After 3 consecutive unsuccessful SSH login attempts, login lockout is enabled for 15
minutes.
Login and logout audit logging is enabled.
DoD login banner is enabled.
If the Security button setting is changed in any way, even if it is toggled back to its
original setting, the password is automatically reset to the default for the chosen
setting. You MUST use the new default of 1988 (Standard Security) or Amx1234!
(Secure or DoD) to re-enter the Protected Settings page.