Eclipse - Fujitsu Ten CD5030 Car Stereo System User Manual


 
70
Various Settings
This resets the adjustment values
saved in the [1] to [4] buttons to the
defaults.
To cancel initializing, press the [ /
BAND] button.
ATTENTION
For the default values, see Parametric
equalizer adjustment (see page 68).
Automatically adjusting the
equalizer mode (Auto EQ)
You can measure the frequency characteristics
(value) in the vehicle to automatically adjust them
to the smooth characteristics with low distortion
based on the measurement data if the optional
measurement microphone (MEI-100) is
connected to this system. The measurement
result can be referred to when adjusting the
parametric equalizer.
ATTENTION
• Adjust Time Alignment (refer to page 71)
and Crossover (refer to page 73) before
measuring frequency characteristics.
• When measuring frequency characteristics,
Loudness setting is automatically
cancelled.
• Close all doors and windows while
measurement is in progress.
Measuring frequency characteristics
Align the microphone with the actual
ear position and attach it to the
headrest or other appropriate fixture.
(Attach the microphone using tape or
string.)
After pressing the button, a 10-second
countdown begins. Leave the vehicle
during that time.
After ten seconds, pink noise will be
output from the speakers and the
measurement of the frequency
characteristics will start. The
“Measuring" message appears on the
display while measurement is in
progress.
When measurement is completed, the
measurement results will appear on
the display. You can adjust the volume
(by turning the [VOL] knob) and restart
measurement while it is in progress.
Press the [ /BAND] button once more
to cancel measurement.
The measurement result can be
referred to when adjusting parametric
equalizer.
ATTENTION
Bluetooth is temporarily disconnected while
measuring frequency characteristics.
2
Press the [ENTER] button.
CAUTION
1
2
In order to make the measurement of
frequency characteristics easier, slight
errors may occur in the measurement data
under some circumstances when this
function is used. In addition, it is not
equivalent to the precise measurements
that can be made by specialist measuring
devices.
1
Connect the RCA connector of the
optional microphone (MEI-100) to
the L-CH of the AUX jack of the
main unit.
2
Hold down the [ENTER] button on
the PEQ screen for more than one
second.