Emsa HS500E Car Stereo System User Manual


 
CHAPTER 3: RFID COMMANDS
3.2 RFID C OMMANDS
The HS500E uses a 2-byte Command ID number to specify the type of operation to
perform.
Commands 02, 03 and 05 must include the command prefix “AB” (0xAB), as in
AB03 (for Command 03) .These three commands instruct the HS500E to perform
standard RFID operations such as reading from and writing to an RFID tag.
Commands F1, F3 and F4 must be appended with “00” (0x00), as in F300 (for
Command F3).
Commands F1, F3 and F4 are used to retrieve information or modify
configuration settings that are stored internally in the HS500E Antenna.
Command F2xx is designed to continuously repeat one of the first three commands
(where xx represents
the type of repetitive command). Command F2 is to be
appended with 02, 03 or 05 which evokes R
epetitive Read, Write or Fill commands.
For example,
F202 indicates a Repetitive Read Data command.
3.2.1 RFID Commands Table
Command
ID
Command
Name
Description
(AB) 02 Read Data
Used to read data from contiguous areas
of an RFID tag’s memory.
(AB) 03 Write Data
Used to write data to contiguous areas of
an RFID tag’s memory
.
(AB) 05 Fill Tag
Used to fill a specified area of a tag with a
single data byte value.
F1 (00)
Test LEDs /
Read Info
Used to run an LED diagnostic test and
retrieve the installed software version
number from the HS500E.
F2 (xx)
Start/Stop
Repetitive
Command
Used to start (or stop) the repetitive
execution of a command. (Where xx
represents Commands 02, 03 or 05 for
repeating a Read, Write or Fill command).
F3 (00)
Write IP
Address
Used to write new IP address configuration
settings to the HS500E.
F4 (00)
Reset Battery
Counter
Used to reset the value of a tag’s Battery
Counter.
HS500E – OPERATOR’S MANUAL P/N: 17-1305 REV02 (12-05)
PAGE 25 OF 82