27
206-4278
Installer Menu (Cont.)
008 - MIN VOLUME (Minimum Volume)
This function determines the minimum volume level allowable
with the Volume (VOL) Up/Down control. In this way, for example,
someone cannot set the volume too low to hear. The value range
is from 0 to 63. The factory default is 0, which provides the full
range of volume control, if item 009 MAX VOLUME is set to 63. It
is recommended to set the same value on every TV.
Note: The minimum volume level cannot have a value setting
higher than the maximum volume level (described below).
009 - MAX VOLUME (Maximum Volume)
This function determines the maximum volume level allowable with
the Volume (VOL) Up/Down control. In this way, for example, some-
one cannot set the volume level high enough to disturb others. The
value range is 0 to 63, with 63 as the default, which gives the user
the full range of volume control, if item 008 MIN VOLUME is set to
0. It is recommended to set the same value on every TV.
Note: The maximum volume level cannot have a value setting
lower than the minimum volume level (described above).
010 - MUTE DISABLE
Enables or disables sound mute function. If set to 1, sound cannot
be muted. If set to 0, sound can be muted.
011 - KEY DEFEAT
If set to 1, Key Defeat is enabled, which means that end users
cannot access or navigate within the on-screen menu(s) from the
display panel; i.e., joystick button menu navigation functions will
not be available. Set to 0 to disable Key Defeat. Note that all IR
features remain functional regardless of this setting; users can
always access the TV menus by pressing MENU SETTINGS on
the remote.
015 - SLEEP TIMER
If set to 1, the Sleep Timer feature may be used. If set to 0, the
Sleep Timer is not available.
016 - EN. TIMER (Enable On/Off Timers)
If set to 1, the Timer function is available to the end user and
enabled continuously. Set to 0 to disable On/Off timers.
Note: The TV clock must be set in order for timers to be used.
017 - ALARM
Gives the installer the option of making the Alarm function available
to the end user. If set to 1, the Alarm function is available to the end
user. Set to 0 to disable the Alarm function.
Note: The TV clock must be set before the Alarm function will work.
020 - FEATURE LEVEL
Determines an additional IR code scheme to which the TV will
respond, allowing for the use of unique IR codes based on “bed
number” in a multi-TV single room installation. First determine the
IR mode; then select the bed number.
Values IR Mode Bed #
0 Disabled N/A
16 – 24 Multi-code Remote 1 – 9
Note: For further information, see documentation for the accessory
package that includes the multi-code remote.
021 - V-CHIP (Parental Control)
Set to 1 to activate V-Chip (Parental Control) and have it available
to the end user to lter and control or otherwise restrict program-
ming content that can appear. Set to 0 to turn the V-Chip feature
Off (not available to user); no programming restrictions can be set.
022 - MAX BLK HRS (Maximum Block Hours)
Sets hours from 0 to 99 for the maximum V-Chip (Parental Control)
block hours. Default setting is for 12 blocking hours.
Note: This item is not available in the Installer Menu when item 021
V-CHIP is set to 0 or when item 084 PERMANENT BLK is set to 1.
023 - CAPTION LOCK
If set to 0, captions are OFF when the TV is turned ON. Set to 1 to
use the caption setting congured before the TV was turned OFF
when the TV is turned ON.
028 - CH. OVERIDE (Channel Override)
Applicable for Pass-through Mode only. If set to 1, users can select
channels either with Channel Up/Down or by direct keypad entry.
This setting also allows full access to channel settings in the TV
setup menus (i.e., channels may be added or removed from the
channel lineup, channel labels and icons may be edited, etc.).
If set to 0, the channel lineup is locked. That is, user access to
channel settings in the TV setup menus is restricted, and users
can only tune to the channels that are included in the channel
lineup. Also, in this case, users can only select channels using
Channel Up/Down; direct keypad entry is not available.
029 - OLD OCV (On Command Video™)
Set to 1 to remap the PTC’s direct tune channels for Aux inputs
from 13x to 9x. This allows 2-digit only tuning systems (i.e., legacy
OCV) to direct tune Aux inputs. See also Reference section, “TV
Aux Input Conguration.”
030 - ACK MASK
MPI Communication Parameter. When set to 1, enables ACK
feature of MPI.
031 - POLL RATE
MPI Communication Parameter. Selects poll rate for MPI. Step size
of 16 ms. Changing from default may affect communication via MPI.
032 - TIMING PULSE
MPI Communication Parameter. Sets baud rate for MPI. Step size
of 4.3 uS. Changing from default may affect communication via
MPI.