E-EQ-MX6RG-E-ARC MX6 Reference Guide
Key Value Description
Log 0 Controls the debug function of ScanDemo.
0=Disable
1=Enable, a log file is created in the \IPSM folder
(or as specified with the LogFilename key)
LogFilename /ipsm/scandemo.log Location and name of the ScanDemo log file.
Sound 1 Enables or Disables the audio notifications for an
error or successful decode.
0=Disable
1=Enable, Front Speaker
2=Enable, Back Speaker
3=Enable, Front and Back Speaker
Leds 1 Enables and disables LED notification for an error
or successful decode/data reception.
0=Disable
1=Enable
ContScan 0 Enable and disables continuous scan. If enabled,
data will be continuously decoded and sent to the
application while the trigger key is depressed. If
disabled, the trigger key must be released between
scans.
0=Disable
1=Enable
PowerSave 0
Default: 1
Enables and disables power saving mode. If
enabled, the imager will be automatically
initialized and un-initialized as needed. A slight
delay will occur when the trigger is activated. If
disabled, the imager will be initialized when the
utility starts and un-initialized when the utility
terminates.
0=Disable
1=Enable
Stats 1 Enables and Disables the collection and
displaying of decoding statistics.
0=Disable
1=Enable
AimerDuration 0 Indicates the number of milliseconds that the
scanner aimer should be displayed when the
trigger key has been pressed down, before
attempting to decode a barcode.
If set to 0 the aimer is disabled.
AimerDelay 500 Indicates the maximum delay (milliseconds)
between two consecutives trigger key presses to
not re-display the aimer and attempt an immediate
decode. Only valid if the AimerDelay is > 0.
AimerDurationALR 2000 Similar to AimerDuration, but for ALR mode only