Printer requirements and specifications
Installation Planning Guide 6-5
Environmental specifications
When you select a location for your printer, avoid environments
with extreme variations in temperature and other hazards, such
as excessive dust or humidity. Recommended environmental
ranges for the work area are as follows:
Table 6-5. Printer environmental specifications
Condition Range
Operating
temperature
Recommended:
Minimum:
Maximum:
68° F to 76° F / 20° C to 24° C
50° F / 10° C
85° F / 29° C
Humidity Recommended:
Minimum:
Maximum:
45% ±10%
30%
65%
Altitude: Normal:
Maximum:
Up to 6,000 feet / 1,830 m
above sea level
9,000 feet / 2,743 m above
sea level
Heat dissipation:
DP 155 and 180
(2-stacker
system)
DP 100, 115,
and 135
(2-stacker
system)
Operating:
Standby:
Energy Saver:
Operating:
Standby:
Energy Saver:
32,770 BTU/hour
4,454 BTU/hour
2,700 BTU/hour
28,140 BTU/hour
4,454 BTU/hour
2,700 BTU/hour
Audible noise Operating:
Continuous:
Impulse:
Standby:
Continuous:
Impulse:
82 dB(A)
82 dB(A)
52 dB(A)
N/A