Understanding auto TA and EQ error messages
When correct measurement of car interior acoustic characteristics is not possible using the auto
TA and EQ, an error message may appear on the display. If an error message appears, refer to the
table below to see what the problem is and the suggested method of correcting the problem. After
checking, try again.
Message Cause Action
ERROR-MIC Microphone isnot connected. Plugthe supplied microphone securelyinto
the jack.
ERROR-FSP,ERROR-FLSP,
ERROR-FRSP,ERROR-CSP,
ERROR-RSP,ERROR-RLSP,
ERROR-RRSP,ERROR-SW
The microphonecannot pick upthe
measuring toneof a speaker.
! Confirmthat the speakersare connected
correctly.
! Correctthe input levelsetting of thepower
amp connectedto the speakers.
! Setthe microphone correctly.
ERROR-NOIS The surroundingnoise level istoo
high.
! Stopyour car ina placethat is asquiet as
possible, andswitch off theengine, air condi-
tioner orheater.
! Setthe microphone correctly.