Auto-Shutdown Delay
By default the ‘Enable Auto Shutdown’ is selected, (see the tick
in the box shown in Figure 8-2 on page 8-2). This allows the X20
console to perform an ATX shutdown when the regulator voltage
(external supply voltage) drops below 10.6 Volts.
The X20 Manager window will be displayed when the regulator
voltage falls below 10.6 Volts.
The time displayed in seconds (default is 10 seconds) determines
how long the X20 Manager will wait before the X20 console starts
an ATX shutdown.
The regulator voltage (external supply voltage) has to stay below
the 10.6 Volt threshold for the time delay period before the ATX
shutdown is started. If the voltage is restored above the 10.6 Volt
threshold, then the Auto-Shutdown is stopped.
The delay can be set between (1 and 10 seconds), the delay can be
set using the up and down arrows. A value higher than 10 seconds
will be overridden by the firmware which will automatically start
the ATX shutdown at 10 seconds.
The voltage can be set using the up and down arrows.
NOTICE
The ‘Voltage’ for ‘Regulator Voltage’ is set at 10.6 volts
and should not be changed unless instructed by a
Topcon Precision Agriculture Representative.