Mitsubishi Electronics MR-J2S- A Car Amplifier User Manual


 
8 - 5
8. SPECIAL ADJUSTMENT FUNCTIONS
8.3 Gain changing function
This function can change the gains. You can change between gains during rotation and gains during stop
or can use an external signal to change gains during operation.
8.3.1 Applications
This function is used when:
(1) You want to increase the gains during servo lock but decrease the gains to reduce noise during rotation.
(2) You want to increase the gains during settling to shorten the stop settling time.
(3) You want to change the gains using an external signal to ensure stability of the servo system since the
load inertia moment ratio varies greatly during a stop (e.g. a large load is mounted on a carrier).
8.3.2 Function block diagram
The valid control gains PG2, VG2, VIC and GD2 of the actual loop are changed according to the conditions
selected by parameters CDP (parameter No. 65) and CDS (parameter No. 66).
Valid
GD2 value
GD2
ParameterNo.34
CDS
ParameterNo.66
Command pulse
frequency
Droop pulses
Model speed
External signal
CDP
Comparator
Valid
PG2 value
PG2
ParameterNo.35
Valid
VG2 value
VG2
ParameterNo.37
Valid
VIC value
VIC
ParameterNo.38
CDP
ParameterNo.65
Changing
PG2 PG2B
100
VIC VICB
100
VG2 VG2B
100
GD2 GD2B
100