Furuno MR-J2S-A Car Amplifier User Manual


 
5 - 14
5. PARAMETERS
Class No. Symbol Name and function
Initial
value
Unit
Setting
range
Control
mode
23 FFC Feed forward gain
Used to set the feed forward gain.
At the setting of 100%, droop pulses during constant-speed operation
will be almost “zero”.
Note that sudden acceleration/deceleration will increase overshoot.
As a guideline, set 1s or more as the acceleration/deceleration time
constant to the rated speed when the feed forward gain is set to
100%.
0%0
to
100
P
24 ZSP Zero speed
Used to set the output range of the zero speed signal (ZSP).
50 r/min 0
to
10000
P S T
0Analog speed command maximum speed
Used to set the speed at the maximum input voltage (10V) of the
analog speed command (VC).
Set "0" to select the rated speed of the servo motor connected.
0
r/min 1
to
50000
S
0
25 VCM
Analog speed limit maximum speed
Used to set the speed at the maximum input voltage (10V) of the
analog speed limit (VLA).
Set "0" to select the rated speed of the servo motor connected.
0
r/min 1
to
50000
T
26 TLC Analog torque command maximum output
Used to set the output torque at the analog torque command voltage
(TC
8V) of 8V on the assumption that the maximum torque is
100[%]. For example, set 50 to output (maximum torque
50/100) at
the TC of
8V.
100 % 0
to
1000
T
27 *ENR Encoder output pulses
Used to set the encoder pulses (A-phase, B-phase) output by the
servo amplifier.
Set the value 4 times greater than the A-phase or B-phase pulses.
You can use parameter No. 54 to choose the output pulse setting or
output division ratio setting.
The number of A/B-phase pulses actually output is 1/4 times greater
than the preset number of pulses.
The maximum output frequency is 1.3Mpps (after multiplication by
4). Use this parameter within this range.
For output pulse designation
Set " 0
" (initial value) in parameter No. 54.
Set the number of pulses per servo motor revolution.
Output pulse
set value [pulses/rev]
At the setting of 5600, for example, the actually output A/B-phase
pulses are as indicated below:
4
5600
A B-phase output pulses 1400[pulse]
For output division ratio setting
Set " 1
" in parameter No. 54.
The number of pulses per servo motor revolution is divided by the
set value.
Output pulse
[pulses/rev]
Resolution per servo motor revolution
Set value
At the setting of 8, for example, the actually output A/B-phase
pulses are as indicated below:
A B-phase output pulses 4096[pulse]
8
131072
4
1
4000 pulse/
rev
1
to
65535
P S T
Internal torque limit 1
Set this parameter to limit servo motor-generated torque on the
assumption that the maximum torque is 100[%].
When 0 is set, torque is not produced.
(Note)
TL
Torque limit
0 Internal torque limit 1 (Parameter No. 28)
1 Analog torque limit internal torque limit 1
: Analog torque limit
Analog torque limit
internal torque limit 1
: Internal torque limit 1
Expansion parameters 1
28 TL1
Note.0 :TL-SG off (open)
1 :TL-SG on(short)
When torque is output in analog monitor output, this set value is the
maximum output voltage (
8V). (Refer to Section 3.4.1, (5))
100 % 0
to
100
P
S T