15 - 61
15. ABSOLUTE POSITION DETECTION SYSTEM
6) Writing absolute position data to A1SD75
The slot number and buffer address of the X-axis current value changing area are changed from
[DTOP H0001 K41 D3 K1] to [DTOP H0000 K1154
D3 K1] 14). When the current value is changed
in the A1SD75, the current feed value is changed at the start of positioning data No.9003.
Therefore, the starting program for positioning data No.9003 15) is added.
7) X-axis data set type home position return program
The slot numbers and buffer addresses of the X-axis home position address changing area are
changed from [DTOP H0001 K7912 D9 K1] to [DTOP H0000 K72
D9 K1] and from [DFROP
H0001 K7912 D9 K1] to [DFROP H0000 K72 D9 K1] 17).
The slot number and buffer address of the X-axis current value changing area are changed from
[DTOP H0001 K41 D3 K1] to [DTOP H0000 K1154
D3 K1] 18). When the current value is changed
in the A1SD75, the current feed value is changed at the start of positioning data No.9003.
Therefore, the starting program for positioning data No.9003 19) is added.
8) Y-axis sequence program, Y-axis data set type home position return program.
The slot numbers and buffer addresses are changed as indicated by 20).
9) Writing absolute position data to AD75
The A1SD75 (AD75) allows the current position to be changed only when the ready signal of the
Servo amplifier is on. Therefore, if the CPU scan is fast, the program for A1SD71 may change
the current position before the ready signal switches on. 7) is added because the current position
must be changed after it has been confirmed that the drive unit ready signal of the A1SD75
(D75) has switched on/off.
10) ABS coordinate error detection
As the A1SD75 (AD75) can handle the negative-polarity coordinate position that the A1SD71
could not handle, the program for ABS coordinate error detection is deleted. 13)
11) Dog type home position return program
Due to the changes in wiring described in (4), (a), 4) of this section, the program for
outputting the clear signal (Y35) after completion of a home position return is required. 16)