Hydraulic
System
Reelmaster 6500-D/6700-D Hydraulic SystemPage 4 - 95
Removal (Fig. 65)
1. Park machine on a level s urface, lower cutting units,
stop engine, engage parking brake, and remove key
from the ignition switch.
Note: The electrical harness does not have to be dis-
connected to remove the right fender and control con-
sole from the frame.
2. Remove right fender with control console attached
enough to allow removal of the hydraulic reservoir.
3. Drainreservoirintoasuitablecontainer(seeChange
Hydraulic Fluid).
4. Remove oil tank.
Inspection
1. Clean hydraulic reservoir and suction strainer with
solvent.
2. Inspecthydraulic reservoirfor leaks, cracks, or other
damage.
Installation (Fig. 65)
1. Install reservoir.
Note: When applying Permabond LH150 or equiva-
lent to the threads of the suction strainer, do not apply
sealant to the first thread.
2. Apply Permabond LH150 or equivalent to the
threads of the suction strainer.
3. Using a wrench, turn strainer into port at least 1-1/2
to 2 full turns beyond finger tight, or until fully seated.
4. Apply Never Seez or equivalent to three cap screws
securing the reservoir to the frame.
5. Fill reservoir with hydraulic fluid (see Change Hy-
draulic Fluid).