Audio Authority Car Audio System Car Stereo System User Manual


 
16
Sources, EQs and Amplifiers
Speakers
Note that the front amps and speakers
have matching group numbers as do
the rear amps and speakers. As a rule,
related amps and speakers have match-
ing group numbers; this determines
how the 902 Control Panel, if used,
handles Volume Compensation of the
products in these Groups. Figure 15
shows how the 902/903 Control Panel
would arrange these product groups on
its Product Group display windows.
B. Determine the Module ID settings.
Number the modules in each group to
put the products in the desired order in
the group. Use the following table for
the appropriate module ID setting for
each module.
FRONT AMP
FRONT SPEAKERS
REAR AMP
REAR SPEAKERS
ATTEN.
LEVEL
(STORE)
EQUAL VOLUME COMPARISON
ATTENUATION / SPL
DECIBELS
MUTE
(ADJUST) P-NOISE AUTO-CAL
Theft AlertSilenTouch
123
456
789
0
A
B
C
SECURE
ON / SPL
SUB AMP
SOURCES
PROCESSOR/EQ
SUBWOOFERS
ASD
å Demonstration Network
Patents Pending
Model 902 Control Panel
Figure 15. This is how product groups appear on the 902 Control Panel.
The display shows which product in each group is selected.
Switching Addressing Set the MODULE ID to: Addressing Set the MODULE ID to:
Modules Sequence for Sequence for
910, 922, Product slide rotary 932 slide rotary
958, 942 Positions switch switch Product Grps switch switch
1st module: 1 - 4 0 - 9 0 1 - 8 0 - 9 0
2nd module : 5 - 8 0 - 9 1 9 - 16 0 - 9 1
etc... 9 - 12 0 - 9 2 17 - 24 0 - 9 2
13 - 16 0 - 9 3 25 - 32 0 - 9 3
17 - 20 0 - 9 4 33 - 40 0 - 9 4
21 - 24 0 - 9 5 41 - 48 0 - 9 5
25 - 28 0 - 9 6 49 - 56 0 - 9 6
29 - 32 0 - 9 7 57 - 64 0 - 9 7
33 - 36 0 - 9 8 65 - 72 0 - 9 8
37 - 40 0 - 9 9 73 - 80 0 - 9 9
41 - 44 10 - 19 0 81 - 88 10 - 19 0
45 - 48 10 - 19 1 89 - 96 10 - 19 1
49 - 52 10 - 19 2 97 -99 10 - 19 2
53 - 56 10 - 19 3
57 - 60 10 - 19 4
61 - 64 10 - 19 5
65 - 68 10 - 19 6
69 - 72 10 - 19 7
73 - 76 10 - 19 8
77 - 80 10 - 19 9
81 - 84 20 - 29* 0
85 - 88 20 - 29* 1
89 - 92 20 - 29* 2
93 - 96 20 - 29* 3
97 - 99 20 - 29* 4
How to Use These Tables
Read accross from left to right. For the 1st
module’s addressing sequence (products
one through four) set the MODULE ID to
0 - 9” on the slide switch, and “0” on the
rotary switch.
* Contact the factory if this address is needed.