Mitsubishi Electronics MR-J2S- A Car Amplifier User Manual


 
10 - 12
10. TROUBLESHOOTING
Display Name Definition Cause Action
1. Acceleration/deceleration time
constant is too small.
Increase the acceleration/deceleration
time constant.
2. Torque limit value (parameter
No.28) is too small.
Increase the torque limit value.
3. Motor cannot be started due to
torque shortage caused by power
supply voltage drop.
1. Review the power supply capacity.
2. Use servo motor which provides larger
output.
4. Position control gain 1 (parameter
No.6) value is small.
Increase set value and adjust to ensure
proper operation.
5. Servo motor shaft was rotated by
external force.
1. When torque is limited, increase the
limit value.
2. Reduce load.
3. Use servo motor that provides larger
output.
6. Machine struck something. 1. Review operation pattern.
2. Install limit switches.
7. Encoder faulty Change the servo motor.
AL.52 Error excessive
(Note)
The difference
between the model
position and the
actual servomotor
position exceeds 2.5
rotations.
(Refer to the
function block
diagram in Section
1.2.)
8. Wrong connection of servo motor.
Servo amplifier's output terminals
U, V, W do not match servo
motor's input terminals U, V, W.
Connect correctly.
1. Communication cable breakage. Repair or change communication cable
2. Communication cycle longer than
parameter No. 56 setting.
Set correct value in parameter.
AL.8A Serial
communication
time-out error
RS-232C or RS-422
communication
stopped for longer
than the time set in
parameter No.56.
3. Wrong protocol. Correct protocol.
1. Communication cable fault
(Open cable or short circuit)
Repair or change the cable.AL.8E Serial
communication
error
Serial
communication
error occurred
between servo
amplifier and
communication
device (e.g. personal
computer).
2. Communication device (e.g.
personal computer) faulty
Change the communication device (e.g.
personal computer).
88888 Watchdog CPU, parts faulty Fault of parts in servo amplifier
Checking method
Alarm (88888) occurs if power
is switched on after disconnection
of all cables but the control circuit
power supply cable.
Change servo amplifier.
Note. The error excessive detection for 2.5 revolutions is available only when the servo amplifier of software version B0 or later is used.
For the servo amplifier of software version older than B0, an error excessive alarm occurs when the deviation (deviation counter
value) between the instructed position and the actual servo motor position exceeds 10 revolutions.