95741 Sixth Edition 5-23
Error and Recovery
Error and Recovery
Note: Refer to Chapter 7, Error and Recovery, for specific drive errors.
Errors may be encountered anytime during operation of the CSL. CSL errors,
recovery, and FSCs are discussed in this section.
Note: The 4EXX FSCs are for the CSL only.
Operator Indicator
When the operator indicator (call out 6) is flashing (Figure 5-17), the CSL
detected an operator-intervention condition. Refer to Table 5-5 on page 5-11 for
a description of the
operator indicator.
When the
operator indicator is on constantly, the CSL has detected an error
condition (usually a jammed, incorrectly loaded, or tipped cartridge).
Refer to Jammed Cartridge on page 5-30 for the procedure to remove a
jammed cartridge.
Refer to Drive Failure to Load on page 5-24 to unload an incorrectly
loaded cartridge.
If cartridges are tipped in the input bin and will not load, reposition the
cartridges to clear the malfunction.
Figure 5-17. CSL Operator Panel
1. power indicator
2. activity indicator
3. clean indicator
4. service indicator
5. IPL switch
6. operator indicator
7. system indicator
8. automatic indicator
9. manual indicator
10. Unload switch
11. Menu switch
12. Select switch
13. Operator display
14. Start switch
15. Autoload Mode switch
Note: The IPL switch (5) initiates IPL of the drive only. Use the Power switch on the back of
the CSL to initiate IPL of the CSL.
C53660
123 45 6
7
8
9
10 11
12
13 14 15