StorageTek 9840 Car Stereo System User Manual


 
95741 Sixth Edition 7-3
Dislodge a Stuck Tape
Table 7-2 provides an alphabetical list of operator panel error displays and
recommended actions. Refer to Figure 7-1 on page 7-1 for switch, indicator, and
display locations on the standard and CSL operator panels.
The notation xxxx is a four-character hexadecimal fault symptom code (FSC).
Note: Refer to Error and Recovery in Chapter 5, Cartridge Scratch Loader,
for additional errors for the CSL.
Table 7-2. Error Displays and Instructions
Display Probable Cause Recommended Action
* A steady asterisk (*) indicates
that the drive completed IPL,
and is online but not loaded.
Operator discretion.
*
Offline
An asterisk (*) alternating
with Offline indicates that
drive or CSL is offline.
Operator discretion.
Place drive Online for use by the host.
ASIA DIAGS This is the normal display
during IPL.
Wait for IPL to complete.
Bank n Bad During a boot, a section of
memory (n=1, 2, 3, or 4) is
found bad.
If IPL does not correct the problem, replace
the drive or CSL.
Boot Fail The IPL failed. Initiate IPL again.
If IPL fails again, replace the drive or CSL.
BT Monitor A sequence of switches took
you to an Engineering zone.
IPL the drive or CSL to clear the error.
BldMIRFail Rebuild of tape Media
Information Region (MIR)
unsuccessful.
Note: In code level 1.30.109 and up, error message is replaced by CHK xxxx.
cnhndnsn The hardware revision level
supported by the firmware in
this drive, where:
n=any number 09,
c=controller processor level
h=host side formatter level
d=device side formatter level
s=servo level.
This message occurs when the firmware
level is insufficient to control the hardware
level in the drive.
Install newer firmware level.
CC DIAG This is the normal display
during IPL.
Wait for the IPL to complete.