Pentair Intellitouch ScreenLogic Car Video System User Manual


 
81
IntelliTouch ScreenLogic User’s Guide
IntelliFlo Status and IntelliFlo 4x160 Controls Screen
To access the IntelliFlo 4x160 status and controls screen:
1. From the main ScreenLogic screen, tap the Equipment and IntelliFlo 4x160 tab. When multiple pumps are
installed, the number (address) of the pumps is also displayed. The IntelliFlo screen displays the following:
Status: See page 79 for details.
Flow Rate Settings/Buttons: Displays the assigned pump circuits on and off buttons. These circuits are
configured in the “Configurator” utility (Step 2 of 5 and 4 of 5), see pages 35 and 49. Tap the button to
activate the pump circuit at the specified displayed RPM. The button will then display in yellow indicating
the pump is active. Multiple pump circuit buttons can be active at the same time. For example, if you
activate the fountain pump to run at 1200 RPM, then tap the waterfall button which is set to 2500 RPM,
both buttons will display in yellow at the same time. Without stopping, the pump will ramp up from 1200
to 2500 RPM until it reaches 2500 GPM. If you then tap the waterfall button to deactivate the circuit
(button not displayed in yellow), the pump will ramp the RPM down to the previously set 1200 RPM.
RPM display and Up/Down button: Displays the current speed of the pump in revolutions per minute
(RPM) for the selected pump circuit as configured in the “Configurator” utility (Step 2 of 5 and 4 of 5),
see pages 35 and 49. Tap the Up button to increase the RPM. Tap the Down button to decrease the
RPM. The RPM indicator will display the current status while the pump is operating. If the pump is
operating and you use these buttons to increase or decrease the pump’s RPM, the pump will stop, start
up again and run at the requested RPM setting.
IntelliFlo Output (Pump Off/Pump On): See page 80 for details.
Power Usage (Watts): See page 80 for details.
Flow (GPM) status indicator: See above for details. Note, The “Flow (GPM)” indicator is not
displayed when using an IntelliFlo 4x160.
Filter Status: See page 80 for details.