Teledyne 460L Car Video System User Manual


 
TELEDYNE INSTRUMENTS
460L Instruction Manual Getting Started
05228 Rev B 19
DCN 5164 PRINTED DOCUMENTS ARE UNCONTROLLED
7. Connect the appropriate type of cable to the 16 pin Signal I/O connector inside the
analyzer.
8. A cable may be included with you instrument. If not, Figure 3-12 below illustrates how to
construct wiring for both RS-232 and RS-485
connections.
5
1
2
3
4
6
7
8
9
Serial TXD
Serial GND
Serial RXD
DB9 Female
RS-232
Twisted Pair
RS-485-B
Serial TXD
Serial RXD
RS-485-
A
RS-485
Figure 3-12 Typical RS-232 and RS-485 Connections
3.7.2. Software Setup for Serial Port Communications
NOTE
This section refers to various serial communication commands for the M460M. For
detailed information regarding these commands see Chapter 7.
1. Connect the other end of the cable to your serial Com port on your computer
2. Open up Hyper-terminal or another terminal program and set up a connection with the
settings below. Your com port is most likely COM1.