Teledyne 460L Car Video System User Manual


 
TELEDYNE INSTRUMENTS
Serial Communications 460L Instruction Manual
34 05228 Rev B
PRINTED DOCUMENTS ARE UNCONTROLLED DCN 5164
7.3.6. SETADDR
SYNTAX
<address>SETADDR:<new_address><CR>
DESCRIPTION
Changes the communications address to a new value.
DATA PARAMETERS SENT
new_address is the new address for the monitor; Range for new_address is 1-9.
RESPONSE
<address>:<success_flag>#<checksum><CR>
EXAMPLE
Command:
1SETADDR:2<CR> - Change address from 1 to 2
Response:
1:OK#261<CR> - Change Address Successful
1:FAIL#391<CR> - Change Address Failed
NOTES
The monitor response is from the previous address (1 in the example shown above), but any
further commands must be at new address (2 in the example shown above).
If the address change was successful, after sending back the OK response, the monitor will no
longer respond to commands with address 1.