13. SERVO AMPLIFIERS WITH A LARGE CAPACITY (30k TO 55kW)
13.3 Signals and wiring
WARNING
Any person who is involved in wiring should be fully competent to do the work.
Before wiring, turn off the power and wait for 20 minutes or more until the charge
lamp turns off. Then, confirm that the voltage between L
and L is safe with a
voltage tester and others. Otherwise, an electric shock may occur. In addition,
always confirm from the front of the converter unit whether the charge lamp is off
or not.
Ground the converter unit drive unit and the servo motor securely.
Do not attempt to wire the converter unit drive unit and servo motor until they
have been installed. Otherwise, you may get an electric shock.
The cables should not be damaged, stressed excessively, loaded heavily, or
pinched. Otherwise, you may get an electric shock.
CAUTION
Wire the equipment correctly and securely. Otherwise, the servo motor may
operate unexpectedly, resulting in injury.
Connect cables to correct terminals to prevent a burst, fault, etc.
Ensure that polarity ( , ) is correct. Otherwise, a burst, damage, etc. may occur.
The surge absorbing diode installed to the DC relay designed for control output
should be fitted in the specified direction. Otherwise, the signal is not output due to
a fault, disabling the forced stop (EM1) and other protective circuits.
Converter unit
drive unit
RA
DOCOM
DICOM
Control
output
signal
24VDC
Converter unit
drive unit
Control
output
signal
RA
DOCOM
DICOM
24VDC
Use a noise filter, etc. to minimize the influence of electromagnetic interference,
which may be given to electronic equipment used near the converter unit
drive
unit.
Do not install a power capacitor, surge suppressor or radio noise filter (FR-BIF-(H)
option) with the power line of the servo motor.
When using the regenerative resistor, switch power off with the alarm signal.
Otherwise, a transistor fault or the like may overheat the regenerative resistor,
causing a fire.
Do not modify the equipment.
During power-on, do not open or close the motor power line. Otherwise, a
malfunction or faulty may occur.