13 - 66
13. SERVO AMPLIFIERS WITH A LARGE CAPACITY (30k TO 55kW)
(2) MR-J3-DU30KB4
MR-J3-DU37KB4
[Unit: mm]
240
Approx. 200
Approx. 200
328
128
180
12060
6
219.2
TE2
TE3
TE1
For mounting
MR-J3BAT
Approx. 60
Approx. 80
2- 6 Installation hole
Cooling fan
wind direction
Terminal block layout
(Terminal cover removed)
Mass: 18[kg] (39.7[lb])
TE1
TE2
TE3
L11
L21
PE
Terminal block signal layout
Terminal block screw: M6
Tightening torque: 3.0 [N m]
(26.6 [lb in])
L
L
Terminal block screw: M4
Tightening torque: 1.2 [N m]
(10.6 [lb in])
Terminal block screw: M8
Tightening torque: 6.0 [N m]
(53.1 [lb in])
Terminal block screw: M8
Tightening torque: 6.0 [N m]
(53.1 [lb in])
Mounting screw
Screw size: M5
Tightening torque: 3.2 [N m]
(28.3 [lb in])
UVW