Polycom 1725-11530-200 Rev A1 Car Speaker User Manual


 
Administrator’s Guide - SoundPoint
®
IP / SoundStation
®
IP Installation and Operation
12 Copyright © 2006 Polycom, Inc.
2.2.1.3.4 Ethernet Menu
2.2.1.4 Reset to Factory Defaults
The basic network configuration referred to in the preceding sections can be reset to
factory defaults.
To perform this function, do one of the following during the countdown process in the
bootROM:
• On all phones except the IP 430 and 4000, simultaneously press and hold the 4,
6, 8 and * dial pad keys until the password prompt appears.
• On the IP 430, simultaneously press and hold the 1, 3, 5 and 7 dial pad keys
until the password prompt appears.
• On the IP 4000, simultaneously press and hold the 6, 8 and * dial pad keys until
the password prompt appears.
Enter the administrator password to initiate the reset. Resetting to factory defaults will
also reset the administrator password (factory default password is 456).
Provisioning
String
b
any string The URL used in XML post/response transac-
tions. If empty, the configured URL is used.
This field is disabled when Provisioning Method
is Default.
a. The server user name and password should be changed from the default values. Note that
for insecure protocols the user chosen should have very few privileges on the server.
b. Not available on SoundPoint
®
IP 300 and SoundPoint
®
IP 500 phones.
Name Possible Values Description
CDP Enabled, Disabled If enabled, the phone will use CDP. It also reports
power usage to the switch.
VLAN ID Null, 0 through 4094 Phone’s 802.1Q VLAN identifier.
Note: Null = no VLAN tagging
LAN
a
a. Only available on SoundPoint
®
IP 430 and 601 phones. HD means half duplex and FD
means full duplex.
Auto, 10HD, 10FD,
100HD, 100FD
The network speed over the Ethernet.
The default value is Auto.
PC
a
Auto, 10HD, 10FD,
100HD, 100FD
The network speed over the Ethernet.
The default value is Auto.
Name Possible Values Description