Mitsubishi Electronics MR-J2-03A5 Car Amplifier User Manual


 
12 - 16
12. OPTIONS AND AUXILIARY EQUIPMENT
(b) Cable clamp fitting (AERSBAN-SET)
Generally, the earth of the shielded cable may only be connected to the connector's SD terminal.
However, the effect can be increased by directly connecting the cable to an earth plate as shown below.
Install the earth plate near the servo amplifier for the encoder cable. Peel part of the cable sheath to
expose the external conductor, and press that part against the earth plate with the cable clamp. If the
cable is thin, clamp several cables in a bunch.
The clamp comes as a set with the earth plate.
Srip the cable sheath of
athe clamped area.
cutter
cable
Cable clamp
(A,B)
Cable
Earth plate
External conductor
Clamp section diagram
40(1.57)
x Outline drawing
2-φ5(0.20) hole
installation hole
Earth plate Clamp section diagram
(Note)M4 screw
11(0.43)
3 (0.12)
6 (0.24)
C
A
6
22(0.87)
17.5(0.69)
35(1.38)
35 (1.38)
L or less
10(0.39)
30(1.18)
B
±
0.3(0.01)
7 (0.28)
24
0
-
0.2
Note: Screw hole for grounding. Connect it to
the earth plate of the control box.
(0.24)
24
+0.3
0
(0.940)
(0.940)
[Unit: mm]
([Unit: in.])
Type A B C Accessory Fittings Clamp Fitting L
AERSBAN-DSET
100
(3.94)
86
(3.39)
30
(1.18)
clamp A: 2pcs. A
70
(2.76)
AERSBAN-ESET
70
(2.76)
56
(2.20)
clamp B: 1pc. B
45
(1.77)