5 - 1
5. PARAMETERS
5. PARAMETERS
CAUTION
y Never adjust or change the parameter values extremely as it will make operation
instable.
5.1 Parameter List
5.1.1 Parameter write inhibit
POINT
y After setting the parameter No. 19 value, switch power off, then on to make
that setting valid.
In the MR-J2-03A5 servo amplifier, its parameters are classified into the basic parameters (No. 0 to 19)
and expansion parameters (No. 20 to 49) according to their safety aspects and frequencies of use. In the
factory setting condition, the customer can change the basic parameter values but cannot change the
expansion parameter values. When fine adjustment, e.g. gain adjustment, is required, change the
parameter No. 19 setting to make the expansion parameters write-enabled.
The following table indicates the parameters which are enabled for reference and write by the setting of
parameter No. 19. Operation can be performed for the parameters marked
.
Parameter No. 19 Setting Operation
Basic Parameters
No. 0 to No. 19
Expansion Parameters
No. 20 to No. 49
Reference {
0000
(initial value)
Write {
Reference No. 19 only
000A
Write No. 19 only
Reference {{
000B
Write {
Reference {{
000C
Write {{