Mitsubishi Electronics MR-J2-03A5 Car Amplifier User Manual


 
3 - 37
3. SIGNALS AND WIRING
(3) Pulse train input interface DI-2
Provide a pulse train signal in the open collector or differential line driver system.
(a) Open collector system
1) Interface
Servo amplifier
P24L
Max. input pulse
frequency 200kpps
Approx. 1.2k
PP(NP)
Approx. 10mA
SG
SD
VDD
OPC
P24G
24VDC
2m(78.74in) or less
2) Conditions of the input pulse
0.9
0.1
tc
tHL
tc tLH
tF
tLH = tHL < 0.2µs
tc > 2µs
tF > 3µs
PP
NP