3 - 37
3. SIGNALS AND WIRING
(3) Pulse train input interface DI-2
Provide a pulse train signal in the open collector or differential line driver system.
(a) Open collector system
1) Interface
Servo amplifier
P24L
Max. input pulse
frequency 200kpps
Approx. 1.2k
Ω
PP(NP)
Approx. 10mA
SG
SD
VDD
OPC
P24G
24VDC
2m(78.74in) or less
2) Conditions of the input pulse
0.9
0.1
tc
tHL
tc tLH
tF
tLH = tHL < 0.2µs
tc > 2µs
tF > 3µs
PP
NP